NISSHINBO

SEARCH

Products

  • Photovoltaic Module Manufacturing Equipment
  • Customized Machine

Double Light Source Solar Simulator

  • Crystal
  • Thin-film
  • Compounds

Features

  • Accurate measurement of tandem and triple types of photovoltaic modules.
  • Pulsed light is used, ensuring stable measurement.
  • Measurement of slow responding photovoltaic modules is also possible.
  • No need to reverse modules, facilitating in-line operation.
  • Our unique IPS technology enables high-speed measurement with a measuring time of 7 seconds and a cycle time of 27 seconds per module.
  • Our unique irradiance adjustment method maintains irradiance non-uniformity within ±4%.

Specifications

Model PVS 1114iD
Effective irradiation area 1100 mm × 1400 mm
Light source Xenon and halogen lamps
Spectrum Within ±25% spectral match for the reference solar radiation of AM1.5 specified under JIS C 8911 for wavelength bands of 350 to 500, 500 to 600, 600 to 700, 700 to 800, 800 to 900 and 900 to 1100 nm.
Measured luminance 1000W/m2
Non-uniformity in irradiance Within 4%
Temporal instability of irradiance Within ±0.2% (*) JIS C 8192 temporal instability of irradiance: Grade A
Re-measurement accuracy Pmax: Within ±0.5%
Power supply 3-phase, AC 200 to 220 V, 50/60 Hz, 180 A
Dimensions (L×W×H) 4.90 m × 4.10 m × 2.05 m

Options

  • Module guide (Manual / automatic transfer)
  • Measurement probe arm
  • Hi-pot test function

Page Top